Common AS/400-Related Errors
The following document lists common errors encountered when submitting jobs in AS/400 systems.
Error: No output
The job has no output.
Specific Error Message
[None]
Resolution
If the job has no output, either the LOG parameter or the SPLFACN parameter will need to be specified in the AS400JobAppend parameter. You should do this on the process server level, since all jobs will then use this value. See the section Setting the AS400JobAppend Parameter in the Administration guide.
Error: Job timed out (after a few seconds), or CPF3C53
This error can occur if the job description is set to detach the spool files from the job and hence delete the job.
Specific Error Message
CPF3C53
Resolution
See the section The JobControl Section in the Redwood Server Platform.
Error: CPFDCFC2
Specific Error Message
CPFDCFC2 Error(s) occurred during running of QWPZHPT1
.
Resolution
You need to grant the user you are running the jobs as the *USE permission on QWPZBC
.
The procedure to follow is:
- Do
WRKMSG QSYSOPER
- you should see a message. - Do
WRKPRB
- you should see a problem. - Work with the problem, should see an error.
- The printer (for example
PRT01
) not existing is a red herring, problem is lack of permission onQWPZBC
.
This error occurs if the customer has restricted access to the QWPZBC
object. This object is used to transform the output and log files into a format that can be copied across to Redwood Server.
onsiteTopic